results.tex 8.2 KB

123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173
  1. % !TeX root = main.tex
  2. \chapter{Results}\label{cha:results}
  3. \section{Prestudy}
  4. Since not much was known about the project at this time, it was difficult to find relevant papers on the topic of the standards. Most of the literature was found during the project as new problems was found along the way.
  5. \section{Initial measurement of the old equipment}
  6. The result from the initial measurements are presented, along with the limits, in \autoref{tab:initial_measurements} without the CNA~200 connected and in \autoref{tab:initial_measurements_cna} with the CNA~200 connected.
  7. \begin{table}[h]
  8. \begin{adjustbox}{width=\columnwidth,center}
  9. %\centering
  10. \begin{tabular}{|l|r|r|r|r|r|r|}
  11. \hline
  12. & \multicolumn{3}{c|}{Limits} & \multicolumn{3}{c|}{Measured} \\
  13. Pulse & $U_S$ (\si{\volt}) & $t_d$ (\si{\second}) & $t_r$ (\si{\second}) & $U_S$ (\si{\volt}) & $t_d$ (\si{\second}) & $t_r$ (\si{\second}) \\ [0.5ex]
  14. \hline
  15. Pulse 1, 12 V, Open & $[ -110, -90 ]$ & $[1.6,2.4]$ \si{\milli} & $[0.5,1]$ \si{\micro} & $-99.0$ & $2.10$ \si{\milli} & $540$ \si{\nano} \\
  16. Pulse 1, 24 V, Open & $[ -660, -540 ]$ & $[0.8,1.2]$ \si{\milli} & $[1.5,3]$ \si{\micro} & $-630$ & $1.18$ \si{\milli} & $2.6$ \si{\micro} \\
  17. Pulse 2a, Open & $[ 67.5, 82.5 ]$ & $[40,60]$ \si{\micro} & $[0.5,1]$ \si{\micro} & $76.0$ & $51.0$ \si{\micro} & $750$ \si{\nano} \\
  18. Pulse 3a, Open (1k) & $[ -220, -180 ]$ & $[105,195]$ \si{\nano} & $[3.5,6.5]$ \si{\nano} & $-202$ & $163$ \si{\nano} & $5.2$ \si{\nano} \\
  19. Pulse 3a, Match & $[ -120, -80 ]$ & $[105,195]$ \si{\nano} & $[3.5,6.5]$ \si{\nano} & $-104$ & $134$ \si{\nano} & $5.0$ \si{\nano} \\
  20. Pulse 3b, Open (1k) & $[ 180, 220 ]$ & $[105,195]$ \si{\nano} & $[3.5,6.5]$ \si{\nano} & $202$ & \cellcolor{red!60} $208$ \si{\nano} & $5.1$ \si{\nano} \\
  21. Pulse 3b, Match & $[ 80, 120 ]$ & $[105,195]$ \si{\nano} & $[3.5,6.5]$ \si{\nano} & $102$ & $166$ \si{\nano} & $5.0$ \si{\nano} \\
  22. Load dump A, 12 V, Open & $[ 90, 110 ]$ & $[320,480]$ \si{\milli} & $[5,10]$ \si{\milli} & $93.4$ & $390$ \si{\milli} & $5.8$ \si{\milli} \\
  23. Load dump A, 24 V, Open & $[ 180, 220 ]$ & $[280,420]$ \si{\milli} & $[5,10]$ \si{\milli} & $190$ & $365$ \si{\milli} & $5.2$ \si{\milli} \\
  24. \hline
  25. \end{tabular}
  26. \end{adjustbox}
  27. \caption{The initial manual measurements, measured directly at each generator's output.}
  28. \label{tab:initial_measurements}
  29. \end{table}
  30. \begin{table}[h]
  31. \begin{adjustbox}{width=\columnwidth,center}
  32. %\centering
  33. \begin{tabular}{|l|r|r|r|r|r|r|}
  34. \hline
  35. & \multicolumn{3}{c|}{Limits} & \multicolumn{3}{c|}{Measured} \\
  36. Pulse & $U_S$ (\si{\volt}) & $t_d$ (\si{\second}) & $t_r$ (\si{\second}) & $U_S$ (\si{\volt}) & $t_d$ (\si{\second}) & $t_r$ (\si{\second}) \\ [0.5ex]
  37. \hline
  38. Pulse 1, 12 V, Open & $[ -110, -90 ]$ & $[1.6,2.4]$ \si{\milli} & $[0.5,1]$ \si{\micro} & $-99.2$ & $2.00$ \si{\milli} & \cellcolor{red!60} $450$ \si{\nano} \\
  39. Pulse 1, 24 V, Open & $[ -660, -540 ]$ & $[0.8,1.2]$ \si{\milli} & $[1.5,3]$ \si{\micro} & $-632$ & $1.18$ \si{\milli} & $2.6$ \si{\micro} \\
  40. Pulse 2a, Open & $[ 67.5, 82.5 ]$ & $[40,60]$ \si{\micro} & $[0.5,1]$ \si{\micro} & $76.0$ & $50.0$ \si{\micro} & $770$ \si{\nano} \\
  41. Pulse 3a, Open (1k) & $[ -220, -180 ]$ & $[105,195]$ \si{\nano} & $[3.5,6.5]$ \si{\nano} & $-213$ & $163$ \si{\nano} & $6.2$ \si{\nano} \\
  42. Pulse 3a, Match & $[ -120, -80 ]$ & $[105,195]$ \si{\nano} & $[3.5,6.5]$ \si{\nano} & $-93.2$ & $138$ \si{\nano} & $6.0$ \si{\nano} \\
  43. Pulse 3b, Open (1k) & $[ 180, 220 ]$ & $[105,195]$ \si{\nano} & $[3.5,6.5]$ \si{\nano} & \cellcolor{red!60} $222$ & \cellcolor{red!60} $200$ \si{\nano} & $6.3$ \si{\nano} \\
  44. Pulse 3b, Match & $[ 80, 120 ]$ & $[105,195]$ \si{\nano} & $[3.5,6.5]$ \si{\nano} & $94.0$ & $171$ \si{\nano} & $5.7$ \si{\nano} \\
  45. Load dump A, 12 V, Open & $[ 90, 110 ]$ & $[320,480]$ \si{\milli} & $[5,10]$ \si{\milli} & $93.2$ & $394$ \si{\milli} & $5.8$ \si{\milli} \\
  46. Load dump A, 24 V, Open & $[ 180, 220 ]$ & $[280,420]$ \si{\milli} & $[5,10]$ \si{\milli} & $186$ & $400$ \si{\milli} & $5.1$ \si{\milli} \\
  47. \hline
  48. \end{tabular}
  49. \end{adjustbox}
  50. \caption{The initial manual measurements on the equipment, including the CNA~200.}
  51. \label{tab:initial_measurements_cna}
  52. \end{table}
  53. \section{Test architecture}
  54. \label{result-test-architecture}
  55. The 3rd alternative was chosen because of the convenience of a fully automatic system and because of the electrical safety hazard that alternative 2 would pose due to its live measurement connectors.
  56. \section{Design of dummy loads}
  57. \subsection{Components}
  58. \todo[förklara komponentval]
  59. \subsection{PCB}
  60. \todo[Peta in bilder]
  61. \subsection{Measurement results}
  62. The resistance at the dummy loads are presented in \autoref{tab:four-wire-result}.
  63. \begin{table}[h]
  64. %\begin{adjustbox}{width=\columnwidth,center}
  65. \centering
  66. \begin{tabular}{|l|r|r|}
  67. \hline
  68. Nominal (\si{\ohm}) & Measured $R$ (\si{\ohm}) & Tolerance (\si{\percent}) \\
  69. \hline
  70. 2 & $2.004$ & 0.2 \\
  71. 10 & $9.973$ & 0.27 \\
  72. 50 & $49.954$ & 0.09 \\
  73. \hline
  74. \end{tabular}
  75. %\end{adjustbox}
  76. \caption{The measured resistance of the dummy loads, and the tolerance compared to the nominal values.}
  77. \label{tab:four-wire-result}
  78. \end{table}
  79. \section{Design of the switching fixture and embedded attenuators}
  80. Vishay's CRCW-HP series fitted this description and were easily available.
  81. \subsection{Attenuators}
  82. The \SI{54.7}{\deci\bel} attenuator was divided into two \SI{27.35}{\deci\bel} $\Pi$ attenuator links. When the closest values for the resistors had been chosen, using \SI{56}{\ohm} as shunt resistors and \SI{560}{\ohm} in series, the final attenuation was \SI{53.66}{\deci\bel} for the two links according to the simulation, seen in \autoref{fig:ltspice-att-ideal-54}. The input and output resistance was
  83. The \SI{60.1}{\deci\bel} attenuator was divided into one \SI{27.35}{\deci\bel} $\Pi$ attenuator links \SI{32.75}{\deci\bel}. When the closest values for the resistors had been chosen, using \SI{56}{\ohm} as shunt resistors and \SI{56}{\ohm} in series, the final attenuation was \SI{53.66}{\deci\bel} for the two links according to the simulation, seen in \autoref{fig:ltspice-att-ideal-54}. The input and output resistance was
  84. \autoref{discussion_attenuators}
  85. \subsection{Measurements}
  86. \begin{figure}
  87. \centering
  88. \begin{subfigure}[t]{0.3\textwidth}
  89. \includegraphics[width=\textwidth]{1k_p}
  90. \caption{Plus terminal closed, all other open}
  91. \end{subfigure}
  92. \begin{subfigure}[t]{0.3\textwidth}
  93. \includegraphics[width=\textwidth]{1k_pao}
  94. \caption{Plus terminal open, all other open}
  95. \end{subfigure}
  96. \begin{subfigure}[t]{0.3\textwidth}
  97. \includegraphics[width=\textwidth]{1k_pooc}
  98. \caption{Plus terminal open, all other closed}
  99. \end{subfigure}
  100. \begin{subfigure}[t]{0.3\textwidth}
  101. \includegraphics[width=\textwidth]{1k_m}
  102. \caption{Minus terminal closed, all other open}
  103. \end{subfigure}
  104. \begin{subfigure}[t]{0.3\textwidth}
  105. \includegraphics[width=\textwidth]{1k_mao}
  106. \caption{Minus terminal open, all other open}
  107. \end{subfigure}
  108. \begin{subfigure}[t]{0.3\textwidth}
  109. \includegraphics[width=\textwidth]{1k_mooc}
  110. \caption{Minus terminal open, all other closed}
  111. \end{subfigure}
  112. \begin{subfigure}[t]{0.3\textwidth}
  113. \includegraphics[width=\textwidth]{1k_g}
  114. \caption{Ground terminal closed, all other open}
  115. \end{subfigure}
  116. \begin{subfigure}[t]{0.3\textwidth}
  117. \includegraphics[width=\textwidth]{1k_gao}
  118. \caption{Ground terminal open, all other open}
  119. \end{subfigure}
  120. \begin{subfigure}[t]{0.3\textwidth}
  121. \includegraphics[width=\textwidth]{1k_gooc}
  122. \caption{Ground terminal open, all other closed}
  123. \end{subfigure}
  124. \caption{The measurements made on the attenuators}
  125. \end{figure}
  126. \section{Analysis}
  127. Nah